The board power button keeps blinking red light ( 3 times in around 1 second, then little break and then same thing agen) and the second light of the 'range dots' is showing up (second closest range dot of the charger plug space). Its not blinking, its just there all the time when you plug the charger in.
- Short description on why is the red light blinking when charging the additional 18650 cells.
- When the diagnostic system encounters a problem, it will alert you by flashing a code through the use of the light emitting diode, or LED, lights located on the furnace. By paying close attention to the LED display on your Payne furnace, you can troubleshoot any potential problems as they evolve.
Carnival of rust flac. Variable Speed AccuLink Heat Pumps and Air Conditioners. Variable Speed Alert Codes;
Alert Code | Alert Group |
---|---|
18 | Control Failure |
67 | Temp Sensor Fault |
68 | Defrost Fault |
80 | High Pressure Monitor Fault |
80 | High Pressure Monitor Fault |
88 | Ground fault |
90 | Communication Busy Fault |
91 | Communication Fault |
106 | External Shutdown Fault |
114 | Bad or Missing PM |
155 | Outdoor EEV Motor Fault |
156 | System Low Charge Fault |
159 | Unit Bus Fault |
164 | Outdoor EEV Valve Migrated Open or Closed |
165 | Low Superheat Error |
166 | Low Superheat Error |
172 | Key fault |
174 | Suction Pressure Sensor Fault |
175 | Limp Along Mode |
176 | Modbus Communication Failure |
177 | Drive Current Failure |
178 | DC Voltage Failure |
179 | Power Module Temperature Failure |
180 | Supply Voltage Failure |
181 | Gate Drive Failure-Motor Phase Loss Detection-Stall Detection-ADC Supply Range exceeded |
182 | Startup Algorithm Fault |
183 | Shutdown Algorithm Fault |
184 | Protection Algorithm Fault |
185 | Protection Derating Fault |
186 | MOC Protection Derating Fault |
187 | Evacuation Mode |
188 | Storage Load Failure-State Failure-Bad Configuration-Voltage VCC Low |
189 | Control Board Temperature High |
American Standard Furnace Error Codes Flashes
Integrated Furnace Control Red Led 'Error' Flash Codes
2 Flashes: System Lockout (Retries or Recycles exceeded)
3 Flashes: Draft Pressure Error – Possible problems: a) Venting problem b) Pressure switch problem c) Inducer problem https://abhohtulo1972.mystrikingly.com/blog/aimersoft-converter-mac.
4 Flashes: Open Temperature Limit Switch
5 Flashes: Flame sensed when no flame should be present
6 Flashes: 115 volt AC power reversed, ignitor (Triac) fault, poor grounding or system voltage too low
How to get adobe photoshop cs5. 7 Flashes: Gas valve circuit error Doctor who the adventure games mac.
8 Flashes: Low flame sense
Boosted Board Error Codes 3 Flashing Lights 2017
9 Flashes: Open Inducer Limit switch Nvidia graphics drivers windows 10.
10 Flashes: Inducer communication error
Boosted Board Error Codes 3 Flashing Lights Light
Solid: Internal GV error or Low TH voltage
Solid Red w/Solid Green 'STATUS' LED: Continuous Reset caused by a blown fuse or internal error.
Fault Code Recovery
On power up, last 4 faults, if any, will be flashed on the red LED. The newest fault detected will flash first and the oldest last. There will be a 2 second delay between fault code flashes. Solid red LED error codes will not be displayed. The Green LED will be on solid during last fault recovery. At any other time the control is powered, the Green LED indicator light will operate as shown in Table 14 and the red LED will flash LitePort data (one flash) every 20 seconds.
Fault Code Reset
The last 4 fault codes can be erased from memory by powering up the control with 'G' energized and then applying 'R' to the 'W1' terminal 3 times within 6 seconds. The control will acknowledge the reset by turning on the red LED for 2 seconds.
5 Flashes: Flame sensed when no flame should be present
6 Flashes: 115 volt AC power reversed, ignitor (Triac) fault, poor grounding or system voltage too low
How to get adobe photoshop cs5. 7 Flashes: Gas valve circuit error Doctor who the adventure games mac.
8 Flashes: Low flame sense
Boosted Board Error Codes 3 Flashing Lights 2017
9 Flashes: Open Inducer Limit switch Nvidia graphics drivers windows 10.
10 Flashes: Inducer communication error
Boosted Board Error Codes 3 Flashing Lights Light
Solid: Internal GV error or Low TH voltage
Solid Red w/Solid Green 'STATUS' LED: Continuous Reset caused by a blown fuse or internal error.
Fault Code Recovery
On power up, last 4 faults, if any, will be flashed on the red LED. The newest fault detected will flash first and the oldest last. There will be a 2 second delay between fault code flashes. Solid red LED error codes will not be displayed. The Green LED will be on solid during last fault recovery. At any other time the control is powered, the Green LED indicator light will operate as shown in Table 14 and the red LED will flash LitePort data (one flash) every 20 seconds.
Fault Code Reset
The last 4 fault codes can be erased from memory by powering up the control with 'G' energized and then applying 'R' to the 'W1' terminal 3 times within 6 seconds. The control will acknowledge the reset by turning on the red LED for 2 seconds.
*PLEASE SEND ME ANY COMMENT, SUGGESTION OR CORRECTION YOU MAY HAVE.